Rodent Gait Analysis System
Rodent Gait Analysis System
Rodent Gait Analysis System
Rodent Gait Analysis System

Rodent Gait Analysis System

Vendor: SANS
Type: Animal Research Equipment
The Rodent Gait Analysis System (Top-Gait) is a high-precision rodent gait analysis system designed to study walking patterns and locomotion in rodents. Idea... ... Read More
Price Unit
Quantity
$69,400.00

Want more possibilities ?

Save

$200

Code: RWD200

Ends in 2 Days 23:12:45

COPY
Listing Price :
$69,400.00

Academic pricing and trade in options may be available. Request a quote to receive the best price for your lab.

Perfect Match With
1/2

Delivery timelines will be provided with your quote

Delivery timelines will be provided with your quote

Standard lead time varies by product availability (in-stock items usually 1–3 business days, custom/backordered items 7–21 business days).

90-day return policy

90-day return policy

Eligible items may be returned within 90 days after delivery, subject to our Return Policy.

Notice

Notice

Final delivery schedules and pricing are subject to confirmation in your official quotation. Customs policies may also impact the total cost. Contact us for your best quote.

Share:
Overview
Feature
Advantages
Highlights
Applications
Specifications
Order Information
Case Study
FAQ
Customer Review

overview

The Rodent Gait Analysis System (Top-Gait) is a high-precision rodent gait analysis system designed to quantitatively evaluate walking patterns and locomotion in rodents. Ideal for rat gait analysis, gait analysis mice, and gait analysis mouse studies, it provides sensitive and reproducible measurements to assess neuromuscular dysfunction, spinal cord injuries, arthritis, and neurodegenerative diseases. The system integrates AI-driven software, HD color cameras, a walkway, lighting system, and computer workstation to capture and analyze over 100 gait parameters.

With automatic video recording triggered when rodents enter the ROI, the system ensures efficient data collection. Built-in algorithms classify footprints rapidly, and an interactive correction module allows frame-by-frame review to improve accuracy. Adjustable camera settings—including gain (0–16), exposure time (5000–15000 μs), and frame rate (up to 165 fps)—enable optimized video quality for detailed gait analysis rodents research.

Key Features of the Rodent Gait Analysis System:

  • Two Walkways – Separate lanes for testing and training to improve experimental efficiency.
  • Optional Modules – Gas (0–100 kPa) and sound (1–130 dB) modules to standardize rodent behavior.
  • Automatic Video Recording – Starts when rodents enter ROI, stops on exit, ensuring consistent data capture.
  • AI Footprint Recognition – Rapidly detects and classifies footprints with high accuracy.
  • Interactive Correction – Allows frame-by-frame review to improve reliability of gait analysis.
  • Flexible Camera Control – Adjustable gain, exposure, and frame rate for optimal video quality.

Reliable, efficient, and user-friendly, this rodent gait analysis system provides a comprehensive solution for quantitative locomotion studies in rodents.

Features & Benefits

Adjustable High Speed Color Camera

The software integrates flexible camera parameter adjustment functions, allowing researchers to set camera gain (range 0–16), exposure time (5000–15000), and frame rate (up to 165 fps). These adjustments help optimize video quality for detailed gait analysis.

Intelligent & Automatic Recording

1. Video recording automatically starts when rodents enter the defined ROI area and stops once they leave, ensuring efficient data collection.
2. Parameters such as maximum/minimum run duration, minimum number of compliant runs, and maximum rate of speed change can be preset to maintain recording consistency and reduce acquisition errors.

Automatic Footprint Classification

The built-in algorithm rapidly recognizes and classifies footprints with high accuracy, significantly reducing manual workload and improving experimental efficiency.

Interactive Footprints Measurements & Correction

The Interactive Footprint Correction module enables frame-by-frame review and error detection. Researchers can adjust and restart detection, enhancing the reliability and accuracy of gait analysis results.

Visualization

Classified footprints are highlighted with rectangular boxes in different colors, while a white curve outlines the animal’s body shape.
All footprints along the walkway can be displayed and enlarged for detailed inspection.
The existing footprints can be enlarged to show each detail of the footprints.
Paw landing sequence diagrams illustrate temporal gait patterns.
2D intensity maps show maximum and average paw contact force.
3D intensity diagrams provide real-time visualization of paw pressure distribution.

Advantages

AI-Driven High-Throughput Analysis

Automated detection and classification minimize manual intervention while improving efficiency.

Natural & Voluntary Locomotion

Animals move freely without forced pacing, preserving authentic gait behavior.

High Sensitivity to Subtle Motor Changes

Capable of detecting early-stage or mild impairments across complex disease models.

Fully Integrated & Reproducible Platform

Hardware and software are seamlessly combined to ensure standardized experimental conditions and consistent data output.

Highlights

Dual-Lane Walkway Design

Separate lanes for training and testing improve conditioning efficiency and throughput.

Gas Stimulation Module

Adjustable 0–100 kPa for behavioral standardization and rapid training.

Sound Stimulation Module

1–130 dB (pure tone or white noise) for controlled auditory stimulation.

Behavioral Standardization Support

Enhances experimental consistency across different models and laboratories.

Applications

Neurological and Neurodegenerative Diseases

Parkinson’s Disease (PD)

Alzheimer’s Disease (AD)

Huntington’s Disease (HD)

Amyotrophic Lateral Sclerosis (ALS)

Aging-related motor decline

Neuromuscular and Movement Disorders

Specifications

Parameter Description
Quantitative Parameters >100 gait metrics
Recording Mode ROI-triggered automatic capture
Camera Gain Range 0–16
Exposure Time 5000–15000 μs
Maximum Frame Rate 165 fps
Supported Species Rat & Mouse
System Components Walkway;
HD Camera;
Lighting System;
Software;
Workstation

Order Information

Item No. Product Components
SA114 Gait Fine Analysis System Gait fine analysis system for Rat & Mouse

Case Study

Explore more about our latest projects and innovations through our articles, events, webinars, success stories, and in-depth insights.

Frequently Asked Questions

  • What species is the system compatible with?

    The system supports both mice and rats, with adjustable walkway settings for different body sizes and weights.
  • What's the difference between Top-Gait and and other systems like CatWalk or DigiGait?

    Our system adds AI-powered footprint analysis, dual walkway design, gas-driven walking assistance, and manual correction tools — offering higher data accuracy and flexibility.
  • Can I analyze paralyzed or poorly coordinated animals?

    Yes. With manual acquisition mode, video trimming, and interactive correction tools, the system is ideal for capturing irregular gaits in compromised animals.
  • Is software training required?

    Yes, we can offer both onsite or online training. And our gait software interface is intuitive, and we provide full user manuals and remote support for setup and use.
  • How many parameters can be measured?

    More than 100 gait parameters including stride length, stance time, swing time, and paw pressure intensity.
  • Can I export the data?

    Absolutely. All results can be exportable in .csv and .xlsx format, ready for processing in Excel, SPSS, or other statistical tools. And all the heatmap, chart can be exportable in svg, jpg, png, mp4 format.