Up to $32.20 off
RWD Portable Rat and Mouse Stereotaxic Instrument
RWD Portable Rat and Mouse Stereotaxic Instrument
RWD Portable Rat and Mouse Stereotaxic Instrument
RWD Portable Rat and Mouse Stereotaxic Instrument
RWD Portable Rat and Mouse Stereotaxic Instrument

RWD Portable Rat and Mouse Stereotaxic Instrument

Vendor: RWD Life Science
Type: Stereotaxic & Neurosurgery Systems
Portable rat and mouse stereotaxic instrument with open frame, removable adaptors, 0–55mm adjustable height, double-lead screw, curved nose clamp, and 100μ... ... Read More
Name
Price Unit
Quantity
68809 Portable Rat and Mouse Stereotaxic Instrument SGL M
$3,570.00
68810 Portable Rat and Mouse Stereotaxic Instrument Dual M
$5,050.00
68811 Portable Rat and Mouse Stereotaxic Instrument SGL M Digital
$5,550.00
68812 Portable Rat and Mouse Stereotaxic Instrument Dual M Digital
$8,820.00
68087 Mouse Adaptor
$320.00
68088 Rat Adaptor
$320.00
68301 Rat 18° Ear Bars
$102.00
68306 Mouse 60° Ear Bars
$102.00
68201 Standard Probe Holder-Corner clamping range 0.3-1.5mm
$128.80 $161.00
68217 Cannula Holder clamping diameter 3.5mm
$130.00
68205 Cannula Holder clamping diameter3.5mm
$130.00
68214 Ceramic Ferrule Holder clamping diameter 1.25mm
$170.00
68215 Ceramic Ferrule Holder clamping diameter 2.5mm
$170.00
68206 General Probe Holder clamping range 3-12mm
$130.00
68218 Syringe Holder the syringe barrel clamping range is 6mm-12mm and the syringe needle clamping range is 0.3mm-1.5mm
$200.00
68605 Microdrill Holder clamping diameter 14.5mm
$104.00 $130.00

Want more possibilities ?

Save

$200

Code: RWD200

Ends in 2 Days 23:12:45

COPY
Total Price:
$3,570.00
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Perfect Match With
1/2

Delivery timelines will be provided with your quote

Delivery timelines will be provided with your quote

Standard lead time varies by product availability (in-stock items usually 1–3 business days, custom/backordered items 7–21 business days).

90-day return policy

90-day return policy

Eligible items may be returned within 90 days after delivery, subject to our Return Policy.

Notice

Notice

Final delivery schedules and pricing are subject to confirmation in your official quotation. Customs policies may also impact the total cost. Contact us for your best quote.

Share:
Overview
Feature
Specifications
Order Information
Literature
Customer Review

overview

The portable stereotaxic instrument cancels the traditional U-shaped frame, and the operation space is larger. The adaptor and ear bars are removable for rodents of different weights. The height of the adaptor is adjustable from 0-55mm, and the height of the ear bars is adjustable from 0-45mm, which is convenient for adjusting the level of the skull. The accuracy of non-digital models is 100 μm, and the accuracy of digital display models is 10 μm.

Features & Benefits

Replace the U-frame, enlarge the operating space, more economical and reliable.

Adaptor can be substituted for rat and mouse.

Unique UP indicator to prevent incorrect operation.

Double-lead screw design, more stable and accurate operation.

Relieve eyestrain by light interrupted.

Curved nose clamp secure the animal firmly.

Specifications

1. Base plate size: 400mm x 255mm.
2. Distance between ear bar and base plate: 35.5mm.
3. Ear bar slots with vernier of 0.1mm resolution.
4. Scale range of Ear bars: 35mm with 1mm resolution.
5. Dorsal/Ventral adjustment range for the adaptor: 30mm (+10mm~-20mm) with 0.1mm resolution.
6. Working distance in 3 dimension is 80 mm with precise alignment to 0.1mm resolution.
7. Vertical direction: 180° rotation and lock at any angles.
8. Horizontal direction: 360° rotation and lock at any angles.
9. Dual-lead screws ensure stable, accurate and smooth manipulation.
10. Accuracy and flexibility can be maintained at variable temperatures.
11. Unique anti-clockwise UP mark engraved in the knob prevents incorrect operation.
12. Vertical lock and fixing knob are separated to ensure accurate function at any angle.
13. Replace the U-frame, enlarge the operating space, more economical and reliable
14. Laser engraved scales enable comfortable reading.
15. Ear bar locked plate pressing instead of clamping ensures more stability.
16. Syringe pump, micro camera and drill can be attached to instruments.

Order Information

Category Model Product Description Remark
Stereotaxic host (without accessories) 68809 Portable Rat and Mouse Stereotaxic Instrument, SGL M Standard configuration, non-digital model (accuracy is 100μm), including 68867S base, 68401 3-axis manipulator-left, without adaptor, ear bars, holder and mask.
68810 Portable Rat and Mouse Stereotaxic Instrument, Dual M Standard configuration, non-digital model (accuracy is 100μm), including 68867D base, 68401 3-axis manipulator-left, 68402 3-axis manipulator-right, without adaptor, ear bars, holder and mask.
68811 Portable Rat and Mouse Stereotaxic Instrument, SGL M, Digital Standard configuration, digital model (accuracy is 10μm), including 68867S base, 68409 3-axis digital manipulator-left, without adaptor, ear bars, holder and mask.
68812 Portable Rat and Mouse Stereotaxic Instrument, Dual M, Digital Standard configuration, digital model (accuracy is 10μm), including 68867D base, 68409 3-axis digital manipulator-left, 68410 3-axis digital manipulator-right, without adaptor, ear bars, holder and mask.
Required accessories (optional)* 68087 Mouse Adaptor Only used for portable rat and mouse stereotaxic instrument
68088 Rat Adaptor Only used for portable rat and mouse stereotaxic instrument
68301 Rat 18° Ear Bars -
68306 Mouse 60° Ear Bars -
68201 Standard Probe Holder-Corner, clamping range: 0.3-1.5mm. -
68217 Cannula Holder, clamping diameter: 3.5mm. The clamping part is made of plastic.
68205 Cannula Holder, clamping diameter: 3.5mm. The clamping part is made of metal.
68214 Ceramic Ferrule Holder, clamping diameter: 1.25mm. -
68215 Ceramic Ferrule Holder, clamping diameter: 2.5mm. -
68206 General Probe Holder, clamping range: 3-12mm. -
68218 Syringe Holder, the syringe barrel clamping range is 6mm-12mm, and the syringe needle clamping range is 0.3mm-1.5mm. -
68605 Microdrill Holder, clamping diameter: 14.5mm. Suitable for 78001 microdrill.

Certificate

For Research Use Only (RUO). Not for use in diagnostic procedures or patient testing.

literature

Diao, Y., Cui, L., Chen, Y., Burbridge, T. J., Han, W., Wirth, B., … & Zhang, J. (2018). Reciprocal connections between cortex and thalamus contribute to retinal axon targeting to dorsal lateral geniculate nucleus. Cerebral Cortex, 28(4), 1168-1182.

Fan, X. C., Fu, S., Liu, F. Y., Cui, S., Yi, M., & Wan, Y. (2018). Hypersensitivity of prelimbic cortex neurons contributes to aggravated nociceptive responses in rats with experience of chronic inflammatory pain. Frontiers in molecular neuroscience, 11, 85.

Liu, Y., Lai, S., Ma, W., Ke, W., Zhang, C., Liu, S., … & Shu, Y. (2017). CDYL suppresses epileptogenesis in mice through repression of axonal Nav1. 6 sodium channel expression. Nature communications, 8(1), 1-17.

Tang, Y., Lin, Y. H., Ni, H. Y., Dong, J., Yuan, H. J., Zhang, Y., … & Chang, L. (2017). Inhibiting Histone Deacetylase 2 (HDAC 2) Promotes Functional Recovery From Stroke. Journal of the American Heart Association, 6(10), e007236.

Huang, L., Yuan, T., Tan, M., Xi, Y., Hu, Y., Tao, Q., … & Luo, M. (2017). A retinoraphe projection regulates serotonergic activity and looming-evoked defensive behaviour. Nature communications, 8(1), 1-13.

Zhu, M., Li, H., Gyanwali, B., He, G., Qi, C., Yang, X., … & Tang, A. (2017). Auditory brainstem responses after electrolytic lesions in bilateral subdivisions of the medial geniculate body of tree shrews. Neurological Sciences, 38(9), 1617-1628.

Lei, Z., Wang, D., Chen, N., Ma, K., Lu, W., Song, Z., … & Wang, J. H. (2017). Synapse innervation and associative memory cell are recruited for integrative storage of whisker and odor signals in the barrel cortex through miRNA-mediated processes. Frontiers in cellular neuroscience, 11, 316.

Zhou, H., Xiong, G. J., Jing, L., Song, N. N., Pu, D. L., Tang, X., … & Richter-Levin, G. (2017). The interhemispheric CA1 circuit governs rapid generalisation but not fear memory. Nature communications, 8(1), 1-10.

Zhang, J., Liu, H., Du, X., Guo, Y., Chen, X., Wang, S., … & Zhang, W. (2017). Increasing of blood-brain tumor barrier permeability through transcellular and paracellular pathways by microbubble-enhanced diagnostic ultrasound in a C6 glioma model. Frontiers in neuroscience, 11, 86.

Li, G. F., Zhao, H. X., Zhou, H., Yan, F., Wang, J. Y., Xu, C. X., … & Zhang, H. L. (2016). Improved anatomical specificity of non-invasive neuro-stimulation by high frequency (5 MHz) ultrasound. Scientific reports, 6(1), 1-11.

Liu, M. G., Li, H. S., Li, W. G., Wu, Y. J., Deng, S. N., Huang, C., … & Xu, T. L. (2016). Acid-sensing ion channel 1a contributes to hippocampal LTP inducibility through multiple mechanisms. Scientific reports, 6, 23350.

Zhao, Baisong, et al. “Hyperbaric oxygen pretreatment improves cognition and reduces hippocampal damage via p38 mitogen-activated protein kinase in a rat model.” Yonsei medical journal 58.1 (2017): 131-138.

Zhao, Yunan, et al. “Decreased glycogen content might contribute to chronic stress-induced atrophy of hippocampal astrocyte volume and depression-like behavior in rats.” Scientific reports 7 (2017): 43192.

Espinosa, P., Silva, R. A., Sanguinetti, N. K., Venegas, F. C., Riquelme, R., González, L. F., … & Sotomayor-Zárate, R. (2016). Programming of dopaminergic neurons by neonatal sex hormone exposure: effects on dopamine content and tyrosine hydroxylase expression in adult male rats. Neural plasticity, 2016.

Li, Wei-Guang, et al. “ASIC1a regulates insular long-term depression and is required for the extinction of conditioned taste aversion.” Nature communications 7.1 (2016): 1-15.

Wang, G. Q., Cen, C., Li, C., Cao, S., Wang, N., Zhou, Z., … & Wang, J. (2015). Deactivation of excitatory neurons in the prelimbic cortex via Cdk5 promotes pain sensation and anxiety. Nature communications, 6(1), 1-16.